Understanding Filter Efficiency and Beta Ratios


Filter ratings are an often misunderstood area of contamination control. On several recent occasions, I have witnessed someone describing a filter by its nominal rating. A nominal rating is an arbitrary micrometer value given to the filter by the manufacturer. These ratings have little to no value. Tests have shown that particles as large as 200 microns will pass through a nominally rated 10-micron filter. If someone tries to sell you a filter based on an "excellent" nominal rating of five microns, run away.
Absolute Rating
Another common rating for filters is the absolute rating. An absolute rating gives the size of the largest particle that will pass through the filter or screen. Essentially, this is the size of the largest opening in the filter although no standardized test method to determine its value exists. Still, absolute ratings are better for representing the effectiveness of a filter over nominal ratings.
Back-Basic_Figure1.gif
Figure 1
Beta Rating
The best and most commonly used rating in industry is the beta rating. The beta rating comes from the Multipass Method for Evaluating Filtration Performance of a Fine Filter Element (ISO 16889:1999).
Table 1. Effect of Filtration Ratio (Beta Ratio) on Downstream Fluid Cleanliness
To test a filter, particle counters accurately measure the size and quantity of upstream particles per known volume of fluid, as well as the size and quantity of particles downstream of the filter. The ratio is defined as the particle count upstream divided by the particle count downstream at the rated particle size. Using the beta ratio, a five-micron filter with a beta 10 rating, will have on average 10 particles larger than five microns upstream of the filter for every one particle five microns or greater downstream.
The efficiency of the filter can be calculated directly from the beta ratio because the percent capture efficiency is ((beta-1)/beta) x 100. A filter with a beta of 10 at five microns is thus said to be 90 percent efficient at removing particles five microns and larger.
Caution must be exercised when using beta ratios to compare filters because they do not take into account actual operating conditions such as flow surges and changes in temperature.
A filter's beta ratio also does not give any indication of its dirt-holding capacity, the total amount of contaminant that can be trapped by the filter throughout its life, nor does it account for its stability or performance over time.
Nevertheless, beta ratios are an effective way of gauging the expected performance of a filter.
I hope this new knowledge of filter efficiency ratings enables you to make a more informed purchase the next time you buy a filter.
Editor's Note
An estimate of the dirt-holding capacity is generated as a sub-part of ISO 16889:99.
About the Author
Jeremy Wright's role as technical consultant for Noria Reliability Solutions (NRS) has him furthering his skills as a lubrication specialist by teaching on-site seminars for a variety of clients and conducting Lubrication Process Design (LPD) consulting services for several industries.
Jeremy is a certified Machinery Lubricant Analyst (MLA) Level I and Level II and Machinery Lubrication Technician (MLT) Level I by the International Council for Machinery Lubrication (ICML). In addition, he is a Certified Maintenance Reliability Professional (CMRP) by the Society for Maintenance and Reliability Professionals (SMRP).

Popular posts from this blog

Vertical Lube Oil Pumps (Model VCRE)

Lube oil pumping applications demand a pump that provides reliability and extended service life with a minimum of maintenance. The typical Lube Oil pump must also be capable of operation over a wide range of temperature and liquid viscosity conditions. The VCRE family of pumps is designed specifically with these requirements in mind. The VCRE lube oil pump is a vertically submerged pump that utilizes an ANSI standard hydraulic construction, enclosed bearing housing, and welded piping construction which eliminates the inherent maintenance and leakage problems associated with other pumps. During operation, axial and radial thrust loads are controlled by Buffalo’s exclusive modified casing volute and impeller design.  is backed by extensive field-proven experience in designing pumps to handle any lube oil application. This experience also provides flexibility in assisting OEM’s contractors and end-users in designing a sound instal...

Motorcycle Shaft Drive Grease

General Purpose Grease Grease has several uses on a motorcycle. It's there to protect parts from water, to keep rubber and plastic seals from drying out, and to provide lubrication. Generally speaking, grease is just a reduced fat. In fact, you can find several companies who call their grease bases "soap." The choice for a general purpose grease to protect from water, keep seals moist, and provide lubrication is easy. If you're going to do your own maintenance, I recommend you get Mobil-1 or Valvoline synthetic grease for general purposes, about $6 / pound anywhere. This stuff can handle temperatures higher and lower than you'll ever get near. A one pound jar should last you about 15 years. Shaft Drive Gear Maintenance There are two types of maintenance you must do on a shaft drive bike. At your rear wheel there are pinion gears where the spinning drive shaft motion is turned 90 degrees into the rear wheel motion. These gears are bathed in oil which much be c...

Understanding Ferrous Density

As part of my job, I regularly present oil analysis training seminars. One of the tests we discuss is ferrous density. I find that this test is seldom well understood, and, probably as a result, is seldom used. Explanation of the Test Ferrous density is the density of ferrous, or more correctly, of ferromagnetic particles distributed in the oil. The other ferromagnetic elements that one might encounter in lubricated components are nickel and cobalt, but in practice, these elements are likely to be present only in comparatively small quantities. Therefore, we are effectively measuring the concentration of magnetic steel alloys. There is no single way to conduct a ferrous density analysis. There are many ways of performing this rather essential test. Perhaps the two most common are the direct-reading ferrography, a technique which uses light blockage analysis of material deposited on a glass slide; and electromagnetic induction, which measures the voltage induced in a current-carrying ...