Skip to main content

Lube-Tips - The 10% Filtration Rule of Thumb

Lube-Tips
View this email in your browser.
lube-tips newsletter

  In This Issue
 
    
» The 10% Filtration Rule of Thumb
» 5 Strategies for Extending Oil Changes
» Lube-Trivia: Reasons for Oil Viscosity Loss
» Entire Plant Converts to Bio-Lubes in 11 Days

The 10% Filtration Rule of Thumb

As a general guideline when periodically decontaminating a lubricant or hydraulic oil sump, the maximum pump displacement should be only 10% of the total volume of oil to be filtered. A 10 gallon reservoir requires no more than 1 gallon per minute for decontamination. Too much may cause a temperature increase and possible foaming and lubricant starvation. Too little pump displacement will require excessive filtration time.

Compare the latest and most effective offline filters, breathers, spin-on's, magnetic filters, water removing filters and more in the Reliable Plant 2010 Exhibit Hall.

Related Topic Pages: contamination control, filter carts, oil filters


Print This Pass for a Lubrication Excellence Learning Session
Attend one learning session at Lubrication Excellence 2010. Includes admission to exhibit hall, receptions, keynote session and more. Nashville, Tennessee - August 31 - September 2.
Printable PDF Pass


5 Strategies for Extending Oil Changes

In this article, Jim Fitch describes some common, and a few not-so-common methods for reducing lubricant consumption and extending drain intervals.
Read the article ...


Lube-Trivia: Reasons for Oil Viscosity Loss

Test your knowledge and prepare for ICML lubrication and oil analysis certification.

Question: Name two possible causes of viscosity loss.

Get the answer.


Entire Plant Converts to Bio-Lubes in 11 Days

This Donatos pizza plant flushed all machines and converted the entire facility from synthetics to bio-based lubricants in just 11 days. Uptime is at a record high.
Read the article ...


Level I Machinery Lubrication Training and Certification
Build a sound foundation for an effective lubrication program with Noria skills training and ICML certification. Printable Brochure


White Papers

Explore Our Topic Pages

Noria Training Calendar


AUGUST 2010

Reliable Plant 2010
August 31 - September 2 - Nashville, TN

SEPTEMBER 2010

Introduction to Machinery Lubrication and Oil Analysis
September 21-23 - Las Vegas, NV

OCTOBER 2010

Introduction to Machinery Lubrication and Oil Analysis
October 5-7 - Mobile, AL

Oil Analysis Basics
October 26-28 - Chicago, IL



 

Follow us on twitter


linkedin

Join our LinkedIn Group

Lube-Tips™ is published by:
Noria Corporation, 1328 E. 43rd Ct., Tulsa, OK 74105 USA.
(918) 749-1400

Lube-Tips is also published in Spanish.

Because results will vary widely based on a number of factors, Noria Corporation cannot warrant the results of any information within this e-mail.

©2010 Noria Corporation

» Receive your own subscription to Lube-Tips

 

» Machinery Lubrication Magazine
» Browse Topics
» ReliablePlant.com
» Book Store
» Buyers Guide
» Lubrication Glossary

 


This email was sent to abelkefa.oilss@blogger.com by newsletters@noria.com because you signed up for this mailing list.
To ensure delivery of emails to your inbox, please add newsletters@noria.com to your address book or safe sender list.
If you are having trouble viewing this email, click here.
to Unsubscribe to future emails. To Report Abuse click here.
  Privacy policy
1328 E 43rd Court Tulsa, OK 74105

Popular posts from this blog

Vertical Lube Oil Pumps (Model VCRE)

Lube oil pumping applications demand a pump that provides reliability and extended service life with a minimum of maintenance. The typical Lube Oil pump must also be capable of operation over a wide range of temperature and liquid viscosity conditions. The VCRE family of pumps is designed specifically with these requirements in mind. The VCRE lube oil pump is a vertically submerged pump that utilizes an ANSI standard hydraulic construction, enclosed bearing housing, and welded piping construction which eliminates the inherent maintenance and leakage problems associated with other pumps. During operation, axial and radial thrust loads are controlled by Buffalo’s exclusive modified casing volute and impeller design.  is backed by extensive field-proven experience in designing pumps to handle any lube oil application. This experience also provides flexibility in assisting OEM’s contractors and end-users in designing a sound instal...

Motorcycle Shaft Drive Grease

General Purpose Grease Grease has several uses on a motorcycle. It's there to protect parts from water, to keep rubber and plastic seals from drying out, and to provide lubrication. Generally speaking, grease is just a reduced fat. In fact, you can find several companies who call their grease bases "soap." The choice for a general purpose grease to protect from water, keep seals moist, and provide lubrication is easy. If you're going to do your own maintenance, I recommend you get Mobil-1 or Valvoline synthetic grease for general purposes, about $6 / pound anywhere. This stuff can handle temperatures higher and lower than you'll ever get near. A one pound jar should last you about 15 years. Shaft Drive Gear Maintenance There are two types of maintenance you must do on a shaft drive bike. At your rear wheel there are pinion gears where the spinning drive shaft motion is turned 90 degrees into the rear wheel motion. These gears are bathed in oil which much be c...

Understanding Ferrous Density

As part of my job, I regularly present oil analysis training seminars. One of the tests we discuss is ferrous density. I find that this test is seldom well understood, and, probably as a result, is seldom used. Explanation of the Test Ferrous density is the density of ferrous, or more correctly, of ferromagnetic particles distributed in the oil. The other ferromagnetic elements that one might encounter in lubricated components are nickel and cobalt, but in practice, these elements are likely to be present only in comparatively small quantities. Therefore, we are effectively measuring the concentration of magnetic steel alloys. There is no single way to conduct a ferrous density analysis. There are many ways of performing this rather essential test. Perhaps the two most common are the direct-reading ferrography, a technique which uses light blockage analysis of material deposited on a glass slide; and electromagnetic induction, which measures the voltage induced in a current-carrying ...