Coupling Grease Application

When changing the lubricating grease in a geared motor coupling, always apply a full coating of grease to the teeth of the coupling. Never fill the coupling housing completely with a grease gun due to expansion of the grease as the motor comes up to running temperature.This expansion of the grease will apply internal coupling pressure pushing the motor shaft off magnetic center and onto the thrust surface of your bearing, causing bearings to overheat and lead to early bearing failure.

Even after hand packing the coupling, the motor should be run up to operating temperature then shut down and the grease plug removed to allow excess grease and pressure to be released. (Wesley Jacobs, director of maintenance services, Missouri American Water Company)

Join us for oil analysis skills training
in Chicago on October 26-28.


QUINTOLUBRIC® Hydraulic Fluids Best-In Class Performance
QUINTOLUBRIC® offers improved thermal stability, increased oxidation stability and longer fluid life. These Fire-Resistant fluids retain unsurpassed biodegradability and non-toxic features. Delivered on time, every time!
quintolubric.com


Making Good Environmental Choices for Lubricants

Making good environmental lubricant choices does not have to compromise equipment reliability or functionality. This article discusses several options to consider.

FULL STORY

Contamination Control System – CCS 4
Mobile measuring system for determining the particle size distribution of contamination, water saturation, fluid temperature.
Obtained measurement results: a base to evaluate the wear condition of hydraulic components, damage detection.

www.internormen.com


What Centrifugal Separators Remove From Oil

Test your knowledge and prepare for ICML lubrication and oil analysis certification.

Question: What types of contaminants might a centrifugal separator remove?

GET THE ANSWER

Level I Machinery Lubrication Training and Certification
Build a sound foundation for an effective lubrication program with Noria skills training and ICML certification.
View Full Brochure



Containing Reservoir Contaminant Populations

While demographers busily count the world's population, manufacturers are fighting against growing particle populations within lube oil and hydraulic systems. Particles and people have little in common except that each has the propensity to increase rapidly in large numbers. 

FULL STORY

White Papers:

Noria Training Calendar
OCTOBER 2010

Introduction to Machinery Lubrication and Oil Analysis
October 5-7 - Mobile, AL

Oil Analysis Basics
October 26-28 - Chicago, IL

NOVEMBER 2010

Introduction to Machinery Lubrication and Oil Analysis
November 9-11 - Louisville, KY

Calendar | Courses | Online Training | Certification


Explore Our Topic Pages
Connect with Us
Follow us on twitterVisit us on facebookJoin our group

Lube-Tips is published by:
Noria Corporation, 1328 E. 43rd Ct., Tulsa, OK 74105 USA.
(918) 749-1400

Receive your own copy of Lube-Tips
Subscribe to our other e-newsletters

©2010 Noria Corporation

 

» MachineryLubrication.com
» ReliablePlant.com
» Noria Corporation
» Bookstore
» Buyers Guide

 

 


This email was sent to abelkefa.oilss@blogger.com by newsletters@noria.com because you signed up for this mailing list.
To ensure delivery of emails to your inbox, please add newsletters@noria.com to your address book or safe sender list.
If you are having trouble viewing this email, click here.
to Unsubscribe to future emails. To Report Abuse click here.
  Privacy policy
1328 E 43rd Court Tulsa, OK 74105

Popular posts from this blog

Vertical Lube Oil Pumps (Model VCRE)

Lube oil pumping applications demand a pump that provides reliability and extended service life with a minimum of maintenance. The typical Lube Oil pump must also be capable of operation over a wide range of temperature and liquid viscosity conditions. The VCRE family of pumps is designed specifically with these requirements in mind. The VCRE lube oil pump is a vertically submerged pump that utilizes an ANSI standard hydraulic construction, enclosed bearing housing, and welded piping construction which eliminates the inherent maintenance and leakage problems associated with other pumps. During operation, axial and radial thrust loads are controlled by Buffalo’s exclusive modified casing volute and impeller design.  is backed by extensive field-proven experience in designing pumps to handle any lube oil application. This experience also provides flexibility in assisting OEM’s contractors and end-users in designing a sound instal...

Motorcycle Shaft Drive Grease

General Purpose Grease Grease has several uses on a motorcycle. It's there to protect parts from water, to keep rubber and plastic seals from drying out, and to provide lubrication. Generally speaking, grease is just a reduced fat. In fact, you can find several companies who call their grease bases "soap." The choice for a general purpose grease to protect from water, keep seals moist, and provide lubrication is easy. If you're going to do your own maintenance, I recommend you get Mobil-1 or Valvoline synthetic grease for general purposes, about $6 / pound anywhere. This stuff can handle temperatures higher and lower than you'll ever get near. A one pound jar should last you about 15 years. Shaft Drive Gear Maintenance There are two types of maintenance you must do on a shaft drive bike. At your rear wheel there are pinion gears where the spinning drive shaft motion is turned 90 degrees into the rear wheel motion. These gears are bathed in oil which much be c...

Understanding Ferrous Density

As part of my job, I regularly present oil analysis training seminars. One of the tests we discuss is ferrous density. I find that this test is seldom well understood, and, probably as a result, is seldom used. Explanation of the Test Ferrous density is the density of ferrous, or more correctly, of ferromagnetic particles distributed in the oil. The other ferromagnetic elements that one might encounter in lubricated components are nickel and cobalt, but in practice, these elements are likely to be present only in comparatively small quantities. Therefore, we are effectively measuring the concentration of magnetic steel alloys. There is no single way to conduct a ferrous density analysis. There are many ways of performing this rather essential test. Perhaps the two most common are the direct-reading ferrography, a technique which uses light blockage analysis of material deposited on a glass slide; and electromagnetic induction, which measures the voltage induced in a current-carrying ...