Changing Lubricant Type? Check This First.

When changing lubricant brands or types, be certain that the new lubricant is chemically compatible with the old. Although you may be adding the new lubricant to an empty and clean reservoir, residual old lubricant will be in the lubrication system piping and metering devices.

Related Topic Pages: grease compatibility, oil analysis


New Poly-on-Pallet Lube Cart from IFH Group
Polyethylene container on steel drip pan base delivers 68 gallons of lubricant or other fluids anywhere in the plant. Semi-transparent container shows fluid level. Retractable hose provides dispensing up to 25 ft. from container.
www.ifhgroup.com


14 Tricks for Detecting and Diagnosing Faults

Oil analysis is detective work. This article describes 14 tricks oil analysts can use for avoiding, detecting and troubleshooting lubricant-related machine failures.
Read the article ...


We Can Help You Predict and Avoid Machine Failure
Spectro Inc. specializes in instrumentation for machine and lubricant condition monitoring. The New Spectroil Q100 spectrometer, particle counters, viscometers, Ferrogram makers, FTIR, Infrared and software. Call 978.431.1120 or visit:
www.SpectroInc.com


Advice for Seal Selection

From "The Practical Handbook of Machinery Lubrication"

From a maintenance point of view, many maintenance managers and purchasing agents select replacement seals for the wrong reasons.

In other words, they put seal replacement cost ahead of sealing effectiveness or fluid compatibility. In order to make better decisions regarding seal selection, maintenance personnel, design engineers and purchasers should become more familiar with the types of materials used for seal manufacture and where these materials can be used most effectively.

Read more about "The Practical Handbook of Machinery Lubrication"


Troubleshooting Changes in Oil Viscosity

When an oil's viscosity makes a significant change it is meaningful. This article explains why viscosity changes happen and how to determine the root cause of the change.
Read the article ...


Video: Onsite Grease Testing Made Easy


3-in-1 Field Grease Tests


White Papers

Explore Our Topic Pages

Noria Training Calendar


MARCH 2010

Oil Analysis Basics
23-25  Austin, TX

Advanced Machinery Lubrication
23-25  Austin, TX

APRIL 2010

Introduction to Machinery Lubrication and Oil Analysis
6-8 Minneapolis, MN

Advanced Oil Analysis
6-8 Minneapolis, MN

 


 

Lube-Tips™ is published by:
Noria Corporation, 1328 E. 43rd Ct., Tulsa, OK 74105 USA.
(918) 749-1400

Lube-Tips is also published in Spanish.

Because results will vary widely based on a number of factors, Noria Corporation cannot warrant the results of any information within this e-mail.

©2010 Noria Corporation

» Receive your own subscription to Lube-Tips

 

» Machinery Lubrication Magazine
» ReliablePlant.com
» Book Store
» Buyers Guide
» Lubrication Glossary

 


This email was sent to abelkefa.oils@blogger.com by newsletters@noria.com because you signed up for this mailing list. To ensure delivery of emails to your inbox, please add newsletters@noria.com to your address book or safe sender list. If you are having trouble viewing this email, click here.
to Unsubscribe to future emails. To Report Abuse click here.
  Privacy policy
1328 E 43rd Court Tulsa, OK 74105

Popular posts from this blog

Vertical Lube Oil Pumps (Model VCRE)

Lube oil pumping applications demand a pump that provides reliability and extended service life with a minimum of maintenance. The typical Lube Oil pump must also be capable of operation over a wide range of temperature and liquid viscosity conditions. The VCRE family of pumps is designed specifically with these requirements in mind. The VCRE lube oil pump is a vertically submerged pump that utilizes an ANSI standard hydraulic construction, enclosed bearing housing, and welded piping construction which eliminates the inherent maintenance and leakage problems associated with other pumps. During operation, axial and radial thrust loads are controlled by Buffalo’s exclusive modified casing volute and impeller design.  is backed by extensive field-proven experience in designing pumps to handle any lube oil application. This experience also provides flexibility in assisting OEM’s contractors and end-users in designing a sound instal...

Motorcycle Shaft Drive Grease

General Purpose Grease Grease has several uses on a motorcycle. It's there to protect parts from water, to keep rubber and plastic seals from drying out, and to provide lubrication. Generally speaking, grease is just a reduced fat. In fact, you can find several companies who call their grease bases "soap." The choice for a general purpose grease to protect from water, keep seals moist, and provide lubrication is easy. If you're going to do your own maintenance, I recommend you get Mobil-1 or Valvoline synthetic grease for general purposes, about $6 / pound anywhere. This stuff can handle temperatures higher and lower than you'll ever get near. A one pound jar should last you about 15 years. Shaft Drive Gear Maintenance There are two types of maintenance you must do on a shaft drive bike. At your rear wheel there are pinion gears where the spinning drive shaft motion is turned 90 degrees into the rear wheel motion. These gears are bathed in oil which much be c...

Understanding Ferrous Density

As part of my job, I regularly present oil analysis training seminars. One of the tests we discuss is ferrous density. I find that this test is seldom well understood, and, probably as a result, is seldom used. Explanation of the Test Ferrous density is the density of ferrous, or more correctly, of ferromagnetic particles distributed in the oil. The other ferromagnetic elements that one might encounter in lubricated components are nickel and cobalt, but in practice, these elements are likely to be present only in comparatively small quantities. Therefore, we are effectively measuring the concentration of magnetic steel alloys. There is no single way to conduct a ferrous density analysis. There are many ways of performing this rather essential test. Perhaps the two most common are the direct-reading ferrography, a technique which uses light blockage analysis of material deposited on a glass slide; and electromagnetic induction, which measures the voltage induced in a current-carrying ...