Cloudy Bearing Oil? You May Be Too Late.

Don't depend on visual inspection entirely for detecting water contamination in bearing lubricants. Bearings can lose 75 percent of their life before the oil ever appears cloudy.

Related Articles: bearing lubrication, water in oil, contamination control


Worry-Free Lubrication
Capture the synergy of LE enhanced lubricants™ delivered via continuous, precise application. When you use perma® automatic lubricators, you'll save time and money plus improve quality & safety. That's synergy worth capturing.
Click here for more info


Keep Hydraulic Motors Clean

From the hydraulic motor standards in "Preventive Maintenance and Condition Monitoring Standards":

If the motor is clean you will be able to inspect it properly. Leaks and failures may be found earlier. Corrosion rate is reduced in clean environments.

Read more about "Preventive Maintenance and Condition Monitoring Standards"


LubriMatic Green™ Eco-Friendly Lubricants and Greases
The LubriMatic Green™ family of biobased products includes a variety of spray lubricants, penetrants and greases formulated from biodegradable vegetable oils and have four times the natural lubricity of petroleum-based products. Visit:
www.lubrimaticgreen.com.


Easy Testing for Grease Thickness

Certain greases tend to harden in use and, if this proceeds far enough, can interfere with equipment function. This article describes simple yet adequately accurate method for checking grease thickness that can be accomplished onsite.
Read the article ...


Digging Your Way Out of Poor Lubrication Practices?
Kick-off 2010 with an effective strategy for machinery lubrication. Bury machine failures and attend Noria's Machinery Lubrication and Oil Analysis training.
Learn More


How to Analyze Gear Failures

This article explains the process for analyzing the root cause of a gear failure. Inspection equipment, visual examination, documentation, lab testing, and types of gear failures are discussed.
Read the article ...


White Papers

Explore Our Topic Pages

Noria Training Calendar


MARCH 2010

Oil Analysis Level II
23-25  Austin, TX

Machinery Lubrication Level II
23-25  Austin, TX

APRIL 2010

Machinery Lubrication and Oil Analysis Level I
6-8 Minneapolis, MN

Oil Analysis Level III
6-8 Minneapolis, MN

 


 

Lube-Tips™ is published by:
Noria Corporation, 1328 E. 43rd Ct., Tulsa, OK 74105 USA.
(918) 749-1400

Lube-Tips is also published in Spanish.

Because results will vary widely based on a number of factors, Noria Corporation cannot warrant the results of any information within this e-mail.

©2010 Noria Corporation

» Receive your own subscription to Lube-Tips

 

» Machinery Lubrication Magazine
» ReliablePlant.com
» Book Store
» Buyers Guide
» Lubrication Glossary

 


This email was sent to abelkefa.oils@blogger.com by newsletters@noria.com because you signed up for this mailing list. To ensure delivery of emails to your inbox, please add newsletters@noria.com to your address book or safe sender list. If you are having trouble viewing this email, click here.
to Unsubscribe to future emails. To Report Abuse click here.
  Privacy policy
1328 E 43rd Court Tulsa, OK 74105

Popular posts from this blog

Vertical Lube Oil Pumps (Model VCRE)

Lube oil pumping applications demand a pump that provides reliability and extended service life with a minimum of maintenance. The typical Lube Oil pump must also be capable of operation over a wide range of temperature and liquid viscosity conditions. The VCRE family of pumps is designed specifically with these requirements in mind. The VCRE lube oil pump is a vertically submerged pump that utilizes an ANSI standard hydraulic construction, enclosed bearing housing, and welded piping construction which eliminates the inherent maintenance and leakage problems associated with other pumps. During operation, axial and radial thrust loads are controlled by Buffalo’s exclusive modified casing volute and impeller design.  is backed by extensive field-proven experience in designing pumps to handle any lube oil application. This experience also provides flexibility in assisting OEM’s contractors and end-users in designing a sound instal...

Motorcycle Shaft Drive Grease

General Purpose Grease Grease has several uses on a motorcycle. It's there to protect parts from water, to keep rubber and plastic seals from drying out, and to provide lubrication. Generally speaking, grease is just a reduced fat. In fact, you can find several companies who call their grease bases "soap." The choice for a general purpose grease to protect from water, keep seals moist, and provide lubrication is easy. If you're going to do your own maintenance, I recommend you get Mobil-1 or Valvoline synthetic grease for general purposes, about $6 / pound anywhere. This stuff can handle temperatures higher and lower than you'll ever get near. A one pound jar should last you about 15 years. Shaft Drive Gear Maintenance There are two types of maintenance you must do on a shaft drive bike. At your rear wheel there are pinion gears where the spinning drive shaft motion is turned 90 degrees into the rear wheel motion. These gears are bathed in oil which much be c...

Understanding Ferrous Density

As part of my job, I regularly present oil analysis training seminars. One of the tests we discuss is ferrous density. I find that this test is seldom well understood, and, probably as a result, is seldom used. Explanation of the Test Ferrous density is the density of ferrous, or more correctly, of ferromagnetic particles distributed in the oil. The other ferromagnetic elements that one might encounter in lubricated components are nickel and cobalt, but in practice, these elements are likely to be present only in comparatively small quantities. Therefore, we are effectively measuring the concentration of magnetic steel alloys. There is no single way to conduct a ferrous density analysis. There are many ways of performing this rather essential test. Perhaps the two most common are the direct-reading ferrography, a technique which uses light blockage analysis of material deposited on a glass slide; and electromagnetic induction, which measures the voltage induced in a current-carrying ...